Spectra-precision ProMark 800 Reference Manual Manual de usuario Pagina 386

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 385
374
Query Command Library
observations has been set to be user defined (see
$PASHS,SOM).
Command Format Syntax
$PASHQ,SOM,NAV[*cc]
Parameters
None.
Response Format Syntax
$PASHR,SOM,NAV,s1,s2*cc
Parameters
Example
$PASHQ,SOM,NAV
$PASHR,SOM,NAV,ON,ON*50
Relevant Set
Command
$PASHS,SOM,NAV
See Also $PASHS,SOM
SOM,SNR: Signal-to-Noise Ratio Mask
Function This command is used to read the current setting of the
signal-to-noise ratio mask applied to signal observations. This
mask is active only when applying masks to signal
observations has been set to be user defined (see
$PASHS,SOM).
Command Format Syntax
$PASHQ,SOM,SNR[*cc]
Parameters
None.
Parameter Description Range Default
s1 Mask applied to differential data ON, OFF ON
s2 Mask applied to raw data ON, OFF OFF
*cc Checksum *00-*FF