343
Query Command Library
Parameters
Comments
With no internal battery in, fields f4, d5 and d7 are all empty.
With no external power source applied, field f6 is empty.
Example
$PASHQ,PWR
$PASHR,PWR,6.8,9.1,2,,,11.6,,44*0D
Relevant Set
Command
$PASHS,PWR,PAR
QZS: QZSS Tracking Status
Function This command is used to read the current status of QZSS
tracking.
Command Format Syntax
$PASHQ,QZS[*cc]
Parameters
None.
Parameter Description Range
f1
Battery voltage threshold, in volts, triggering a low-bat-
tery alarm
6.7-8.4
f2
External power voltage threshold, in volts, triggering a
low-power alarm
9.0-28
d3
Power source:
0: Internal battery
1: External battery
2: External DC source
0-2
f4 Battery DC output voltage, in volts 0.0-12.0
d5 Percentage of remaining battery energy 0-100
f6 DC input voltage from external power, in volts 0.0-30.0
d7
Battery charging status:
0: Charging
1: Discharging
2: Fully charged
0-2
d8 Internal temperature, in °Celsius
*cc Checksum *00-*FF