Spectra-precision ProMark 800 Reference Manual Manual de usuario Pagina 275

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 274
263
Query Command Library
$PASHR,ANP,RCV,ASH802147,-2.00,0.70,103.00,-3.4,-2.2,103.80*09
ANP,REF: Antenna Used at the Base
Function This command returns the name of the GNSS antenna
assumed to be used by the base currently sending data to the
interrogated receiver (a rover).
Command Format Syntax
$PASHQ,ANP,REF[*cc]
Parameters
None.
Response Format Syntax
$PASHR,ANP,REF,s1,d2*cc
Parameters
Example $PASHQ,ANP,REF
$PASHR,ANP,REF,ASH111661,1*3D
Relevant Set
Command
$PASHS,ANP,REF
ANR: Antenna Reduction Mode
Function This command is used to read the current setting for the
antenna reduction mode. This setting defines the physical
location on the system for which the position is computed.
Parameter Description Range
s1 Name of the antenna used at the base 31 characters max.
d2
Antenna name preference:
0: s1 is ignored if incoming reference
data include base antenna name
1: s1 is always used; decoded base
antenna name is ignored
0, 1
*cc Checksum *00-*FF