248
Set Command Library
Note
If the chosen station ID is beyond the upper limit in the
applicable range, then the value “31” is chosen instead (i.e.
“31” instead of “56” for example if CMR/CMR+ messages
are broadcast, or “31” instead of “1041” for example if
RTCM 2.3 messages are broadcast).
Relevant Query
Command
$PASHQ,STI
See also $PASHS,BAS
$PASHS,MOD,BAS
SVM: Setting the Maximum Number of Observations in the PVT
Function: This function is used to set the maximum number of code and
doppler observations used in the PVT calculation.
Command Format Syntax
$PASHS,SVM,d1[*cc]
Parameters
Example
Setting the number of observations to 25:
$PASHS,SVM,25*16
Comments This setting affects all the positioning modes, except for the
time-tagged RTK mode for which this limit is hardware coded
and set to 14 satellites.
Relevant Query
Command
$PASHQ,SVM
$PASHQ,PAR
Parameter Description Range Default
d1 Maximum number of observations 0-26 14
*cc Optional checksum *00-*FF -