177
Set Command Library
Parameters
Examples
Selecting DBEN message type “RPC” at 0.5 second:
$PASHS,DBN,TYP,RPC,0.5*26
Selecting DBEN message type “BPS” at 60 seconds:
$PASHS,DBN,TYP,BPS,60*0B
Relevant Query
Command
$PASHQ,DBN,MSI
See Also $PASHS,BAS
$PASHS,BDS
DIP: Server Connection
Function This command is used to connect the receiver to a base via
the base’s IP address or host name.
Command Format Syntax
$PASHS,DIP,RIP,s1,PRT,d2[,LGN,s3,PWD,s4][*cc]
Parameter Description Range
s1 Message type See table below
d2 Output rate, in seconds See table below
*cc Optional checksum *00-*FF
Type Description Range
Default
Output Rate
RPC Code & phase measurement 0, 0.1-0.9 s and 1-300 s 1
BPS Reference station position 0-300 s 30