264
Query Command Library
Command Format Syntax
$PASHQ,ANR[*cc]
Response Format Syntax
$PASHR,ANR,s1*cc
Parameters
Example $PASHQ,ANR
$PASHR,ANR,ON*04
Relevant Set
Command
$PASHS,ANR
See also $PASHS,ANH
ANT: Antenna Height
Function This command is used to read the current setting for the
antenna height.
Command Format Syntax
$PASHQ,ANT[*cc]
Response Format Syntax
$PASHR,ANT,f1,f2,f3,m4,f5*cc
Parameter Description Range
s1
Antenna reduction mode:
OFF: The computed position is assumed to be the
location of the antenna’s L1 phase center.
ON: The computed position is assumed to be the
location of the ground mark.
ARP: The computed position is assumed to be the
location of the Antenna Reference Plane (ARP).
OFF, ON,
ARP
*cc Checksum *00-*FF