Spectra-precision ProMark 800 Reference Manual Manual de usuario Pagina 278

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 277
266
Query Command Library
Parameters
Examples Data recording disabled:
$PASHQ,ATL*2E
$PASHR,ATL,OFF,0,S,1,0*2C
Data recording enabled and in progress:
$PASHQ,ATL*2E
$PASHR,ATL,ON,0,R,0.5,0*79
Data recording is enabled but for some reason (no SD card,
etc.), no data is being recorded:
$PASHQ,ATL*2E
$PASHR,ATL,ON,0,S,0.5,0*78
Parameter Description Range
s1
ON/OFF/AUT status:
ON: Debug data recording is enabled
but will not re-start after a power cycle.
OFF: Debug data recording is disabled.
AUT: Debug data recording is enabled
and will re-start after a power cycle.
ON, OFF, AUT
d2
Indicates which data are recorded:
0: Only data from GNSS board to sys-
tem board are recorded.
1: Only data from system board to
GNSS board are recorded.
2: Data flowing in both directions are
recorded.
0-2
c3
Recording status:
R: The receiver is currently recording
data for debugging.
S: No debug data currently recorded.
R, S
f4 Output rate, in seconds (default: 1 sec.) 0.05, 0.1, 0.2,0.5, 1
d5 Configuration index 0, 1
*cc Checksum *00-*FF
Vista de pagina 277
1 2 ... 273 274 275 276 277 278 279 280 281 282 283 ... 427 428

Comentarios a estos manuales

Sin comentarios