Spectra-precision ProMark 800 Reference Manual Manual de usuario Pagina 181

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 180
169
Set Command Library
Relevant Query
Command
$PASHQ,CMR,MSI
See also $PASHS,BAS
$PASHS,CPD,MOD,BAS
CPD,AFP: Setting the Confidence Level of Ambiguity Fixing
Function This command is used to set the confidence level required of
the ambiguity fixing process. The higher the confidence level,
the more likely the ambiguities are fixed correctly, but the
longer the time it takes to fix them.
Command Format Syntax
$PASHS,CPD,AFP,f1[*cc]
Parameters
Example
Setting the confidence level to 99.9%:
$PASHS,CPD,AFP,99.9*62
Relevant Query
Commands
$PASHQ,CPD,AFP
$PASHQ,CP2,AFP
$PASHQ,CPD
Parameter Description Range Default
f1
Confidence level, in per-
cent, required of ambiguity
fixing process.
Choosing “0” means the
receiver will not try to fix
ambiguities but instead will
stay indefinitely in Float
mode.
0, 95.0, 99.0 or
99.9
99.0
*cc Optional checksum *00-*FF -
Vista de pagina 180
1 2 ... 176 177 178 179 180 181 182 183 184 185 186 ... 427 428

Comentarios a estos manuales

Sin comentarios