Query Command Library
+004.2 +003.5 +002.5 +001.1 -000.7 -002.8 -005.1 +000.0 +000.0
Relevant Set
Commands
$PASHS,ANP,OWN
$PASHS,ANP,REF
$PASHS,ANP,PCO
ANP,OUT: Virtual Antenna
Function This command returns the name of the virtual antenna
currently selected in the receiver.
Command Format Syntax
$PASHQ,ANP,OUT[*cc]
Parameters
None.
Response Format Syntax
$PASHR,ANP,OUT,s1*cc
Parameters
Example $PASHQ,ANP,OUT
$PASHR,ANP,OUT,ADVNULLANTENNA*72
Relevant Set
Command
$PASHS,ANP,OUT
ANP,OWN: Local Antenna Used
Function This command returns the name of the GNSS antenna
currently used by the receiver.
Command Format Syntax
$PASHQ,ANP,OWN[*cc]
Parameter Description Range
s1
Name of the virtual antenna.
If “OFF” is returned, this means no virtual
antenna is selected.
31 characters
max.
*cc Checksum *00-*FF