360
Query Command Library
FRQ: 0 0 0 1 0 30 0 0
TYP: 1009 1010 1011 1012 1013 1019 1020 1029 1033
FRQ: 0 0 0 1 30 0 0 0 31
MSG:
MSG:No User Message
Parameters
Status:
Setup:
Parameter Description Range
SYNC
RTCM status:
*: Corrections from base received in rover
in due time.
<space>: No corrections are received that
would be compatible with the” maximum
age of corrections” requirement.
*, <space>
VER RTCM version V2.3, V3
STID Station ID received from the base 0-4095
STHE Station health index received from the base 0-7 (RTCM2.3)
AGE Age of last message received 0-999
TYPE RTCM message being received or sent
1, 18/19, 20/21, 31,
1001, 1002, 1003,
1004, 1009, 1010,
1011, 1012
MSG
User message received in message type 16,
36 or 1029
90 characters max.
Parameter Description Range
MODE
RTCM Base/Rover mode:
ROV: If the receiver is a rover.
BAS: If the receiver is a base and the
selected differential data type is RT2 or
RT3.
ROV, BAS, OFF
PORT
Communication port:
AUT, in rover mode, when the differential
reception mode is “AUT” (see
$PASHS,CPD,REM).
One or two ports, in rover mode, when the
differential reception mode is “MAN” (see
$PASHS,CPD,REM)
One or two ports, in base mode (see
$PASHS,BAS). Only if RT2 or RT3 is
used.
VER RTCM version V2.3, V3
STI Station ID 0-4095
TYP
Type of RTCM message the receiver gener-
ates (base receiver only)
FRQ Transmit rate of RTCM message, in seconds 0-1800