d. The rod man needs to move back by 0.2
feet to be over the design point. Rather
than take another shot, we will instruct
him to use a tape and place a stake at
that location. Tap the
button to store the point.
e. Enter the following data in the Store
Point (Tape Offset) Dialog Box:
Point Name
:
6
Description
:
Staked
Tape Out/Tape In (+/-)
:
0.2
and tap . This will result in coordinates for the stored
point that are 0.2 feet further from the total station than the
last shot to the prism.
Note: The default value in the
Tape Out/Tape In
field should put you
directly over the design point, assuming you are on line.
Note: Negative
Tape Out/Tape In
values are toward the total station
and positive values are away from the total station.
Point Staking Summary
1. Open a job that contains the design points that you want to stake.
2. Check the job settings.
3. Setup a backsight.
4. Stake the points from the Stake Points
screen.