Survey Pro Reference Manual
R-100
Shots
Number of sets
: is the number of sets that will be taken to the
celestial object.
Reverse Shots
: When checked, reverse shots
will be required with each set. When unchecked,
only direct shots are required.
: accesses the Enter Shot Data
screen,
described below, where the shot data is entered
for the selected observation.
/ : will toggle the selected observation
so that it will be hidden or un-hidden,
respectively. When an observation is hidden, it
will not be used when calculating the final
azimuth.
Note: The / buttons perform the same function as
checking / un-checking the checkbox in front of each observation.
Note: A backsight observation cannot be tossed.
: permanently deletes the most current observation if it is
selected allowing you to shoot that shot again.
: permanently deletes all observations. A warning prompt will
appear before the observations are deleted.