Fieldwork
61
a. Access the ,
screen from the Main Menu.
b. In the
Occupy
Point
field, enter
1
as the
point name.
c. Toggle the /
button to and enter
0
as
the backsight azimuth.
d. Enter an
HI
and
HR
of
5
feet.
e. Leave the
Fixed HR at Backsight
field
unchecked.
f. Confirm that the
Backsight Circle
value is zero. If it displays a
non-zero value, tap the button and set it to
zero.
g. Tap . A map view will open that shows a graphical
representation of the occupy point and backsight direction.
Tap to continue.
Staking Points
4. Stake the first design point (Point 2).
a. Access the , screen. The backsight
information is displayed near the bottom
of the screen. At this point, it is
assumed that your total station is over
the occupy point and its horizontal angle
was zeroed while aiming toward the
backsight.
b. Enter the following data in the Stake
Points screen:
Design point
:
2
Increment
:
1
Height of rod
:
5
and tap .