Spectra-precision Survey Pro CE v3.6 User Manual Manual de usuario Pagina 385

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 407
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 384
Survey Pro Reference Manual
R-228
Scale
The Scale screen will scale the distances of a range of points relative
to a specified base point. This is useful to correct a survey where a
scale factor was inadvertently applied during data collection.
: allows you to select points by
tapping them from a map view.
: allows you to select points by typing
in a point range.
Base point
: The distances to all the selected
points will be scaled relative to this point. (The
coordinates for the base point will not change.)
Scale factor
: is the scale factor that is applied to
the distances from the base point to the selected
points.
Include Elevation in Adjustment
: When checked, the elevations to
the selected points will also be adjusted by the scale factor relative to
the
Base point
.
: will perform the adjustment on the selected points and
change the coordinates accordingly. Information will be written to
the raw data file detailing the adjustment.