Users Manual
102
BS > FS ^ FS > BS
: Shoot backsight, shoot foresight, reverse
scope, shoot foresight, shoot backsight
BS > FS ^> BS > FS
: Shoot backsight, shoot foresight, reverse
scope, shoot backsight, shoot foresight
BS ^ BS > FS ^ FS
: Shoot backsight, reverse scope, shoot
backsight, shoot foresight, reverse scope, shoot foresight
FS ^ FS > BS ^ BS
: Shoot foresight, reverse scope, shoot
foresight, shoot backsight, reverse scope, shoot backsight
FS > BS ^ BS > FS
: Shoot foresight, shoot backsight, reverse
scope, shoot backsight, shoot foresight
FS > BS ^> FS > BS
: Shoot foresight, shoot backsight, reverse
scope, shoot foresight, shoot backsight
Repetition Shots Screen
After the repetition settings are configured for your particular
situation, the Repetition Shots
screen is accessed where the actual
shots are performed.
1. Select , from the
Main Menu. If you have not already defined
your backsight, you will need to do so before
you can access the Repetition Shots
screen.
2. Enter the
Foresight
point name,
Number of
Sets
and
HR
(rod height) in the appropriate
fields.
3. Tap the button to start the process of
shooting all of the sets using the sequence
selected in the Repetition Settings
screen.
4. Prompts will open after every shot that instruct you on which
point to shoot next and when you when you need to flop the scope.
If at least three sets were performed, the
Average (of)
and
Worst
Residual
fields will be filled in after the final shot is taken. The
Average (of)
values are simply average measurements for all of the
shots taken. The
Worst Residual
is the angle or distance
Vista de pagina 107