Survey Pro Reference Manual
R-34
Write Cut Sheet Data Only (No Store Point)
: When checked, as-
built points are not stored to the JOB file when staking points; only
the raw data is written to the RAW file.
Display Left / Right From Rod (non-remote)
: When checked, the
move left or right information will be presented from the rod persons
point of view. When unchecked it will be presented from the total
stations point of view. (This option only applies when a robotic total
station is selected in the Instrument Settings
.)
Display Left / Right From Rod (remote)
: When checked, the move
left or right information will be presented from the rod persons point
of view. When unchecked it will be presented from the total stations
point of view. (This option only applies when a non-robot total station
is selected in the Instrument Settings
.)
Prompt for Layer
: When checked, a prompt to select a layer will
appear before any new point is stored from only the routines under
the Stakeout
menu.
Prompt for Attributes
: When checked, a prompt to select feature
information will appear before any new point is stored from only the
routines under the Stakeout
menu. This also requires that a feature
file be selected from the Files Settings
card, described earlier.
Note: There is no
Prompt for Description
checkbox as in the Surveying
Settings card because you are always prompted for a description
when storing a point from a stakeout routine.
Horizontal Distance Tolerance
: this setting affects the Remote
Staking and Stake to Line routines (Page R-113). When staking to a
line and the prism is located at a perpendicular distance to the
specified line that is within the range set here, a message will state
that you are on the line. When performing Remote Stakeout, the
final graphic screen that is displayed when you are near the stake
point will occur when you are within the distance to the stake point
specified here.
Turn gun to design point
: only applies to motorized total stations.
The following options are available: