Spectra-precision Survey Pro CE v3.6 User Manual Manual de usuario Pagina 237

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 407
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 236
Survey Pro Reference Manual
R-80
Repetition Shots
The Repetition Shots screen is used to perform side shots or traverse
shots using any number of repetitions.
Note: The sequence that the repetition shots are performed is
selected in the Repetition Settings screen (Page R-35).
: located at the top of the screen, is a
shortcut to the Surveying and Repetition
Settings screens (Page R-32 and R-35
respectively).
Foresight
: is the name of the point that will be
stored.
Number of Sets
: is the desired number of sets to
shoot to the backsight and foresight.
Note: One set is equivalent to two shots to the
backsight and foresight point.
HR
: is the rod height.
Average (of)
: shows the average angle or distance to the foresight
from all the shots taken. The value in parenthesis is the total
number of repetitions performed.
Worst Residual
: displays the worst residual calculated from all the
sets of the selected measurement type.
Description
: is the description for the point that is being stored. This
field appears prior to storing the new point.
Note: A residual is the difference between a single measurement and
the average of all the measurements.
Vista de pagina 236
1 2 ... 232 233 234 235 236 237 238 239 240 241 242 ... 406 407

Comentarios a estos manuales