Survey Pro Reference Manual
R-82
Note: prior to storing a point, you may then be prompted for
description, rod height, layer, and/or feature information depending
on the selections made in the Surveying Settings screen.
: accesses the Backsight Setup
screen (Page R-78) where
the current backsight can be modified.
Note: The current backsight information is displayed across the top
of the Traverse / Sideshot screen.
Results
Angle Right
: is the horizontal angle right around the
Occupy Point
from the
Backsight
to the
Foresight Point
.
Azimuth
: is the azimuth from the
Occupy Point
to the
Foresight Point
.
Zenith
: is the zenith angle measured by the total station to the prism.
Slope Dist
: is the slope distance measured by the total station to the
prism.
Horz Dist
: is the horizontal distance from the
Occupy Point
to the
Foresight Point
.
Vert Dist
: is the vertical distance from the
Occupy Point
to the
Foresight Point
.
Point
: is the name of the stored point.
Desc
: is the description of the stored point.
Location N
: is the Y-coordinate of the stored point.
Location E
: is the X-coordinate of the stored point.
Location Z
: is the elevation of the stored point.