Spectra-precision Survey Pro v3.80 Recon iPAQ Reference Manual Manual de usuario Pagina 240

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 261
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 239
Survey Pro Reference Manual
R-234
Scale
The Scale screen will scale the distances of a range of points relative
to a specified base point. This is useful to correct a survey where a
scale factor was inadvertently applied during data collection.
: allows you to select points by tapping
them from a map view.
: allows you to select points by typing in a
point range.
Base point
: The distances to all the selected points will
be scaled relative to this point. (The coordinates for the
base point will not change.)
Scale factor
: is the scale factor that is applied to the
distances from the base point to the selected points.
Include Elevation in Adjustment
: When checked, the
elevations to the selected points will also be adjusted by
the scale factor relative to the
Base point
.
: will perform the adjustment on the selected
points and change the coordinates accordingly.
Vista de pagina 239
1 2 ... 235 236 237 238 239 240 241 242 243 244 245 ... 260 261

Comentarios a estos manuales

Sin comentarios