GPS Reference Manual
70
Rec Interval
: the recording interval set on the Post Process card of the
Job
, Settings screen (page R- 11).
Mem. Threshold
: displays the memory threshold set on the Post
Process card of the Job, Settings screen.
SV Threshold
: the satellite threshold set on the Post Process
card of
the Job
, Settings screen.
HDOP Threshold
: displays the HDOP threshold set on the Post
Process card of the Job, Settings screen.
Note: The threshold fields display
Off
if the Survey Pro Threshold
Manager is turned off.
Last Antenna for this Receiver
: displays antenna information defined
from the Post Processing Antenna
screen, opened from . The
title of this field changes depending on if the antenna has already
been setup.
Measured
: is where you enter the height of the antenna, measured to
the location specified on the Post Processing Antenna
screen.
: opens the Post Processing Antenna
screen (Page R-27)
where the details of the base antenna are defined.
Post Processing Antenna Screen
The Post Processing Antenna screen is used to define the parameters
of the antenna. The screen is identical to the Base Receiver Antenna
screen, which is described on Page R-27.
Start Stop/Go Rx
The Stop/Go Rx Recording screen is used to start or stop recording in
a stop and go receiver’s internal memory and change the recording
interval or antenna height. It is identical to the Static Rx Recording