Survey Pro Reference Manual
R-106
Measure Mode Settings
Job Settings Measure Mode.
The Measure Mode card is used to configure the RTK data collection
settings.
Receiver Dynamics: is where you control the
receiver dynamics for point occupations. There
are two choices
Static on occupy: On starting a point
occupation, receiver is put in static
mode where it calculates position
assuming no motion and applies
advanced averaging techniques for the
most precise solution.
Dynamic always: Receiver is left in
dynamic mode for all point occupations.
Accept Solution Quality: is where you control the solution quality
acceptable for storing measurements. You have two options:
Fixed RTK only: Allows storage of fixed solution only.
Code, Float, or Fix: Allows storage of any differential
solution.
Acceptance Criteria: is where you select to apply criteria to
measurement acceptance. When checked, only measurements with
RMS and/or PDOP values below the threshold will be accepted. To
use less than all three criteria, check this box but enter 0.0 for the
criteria you do not wish to apply.
H RMS: is the horizontal RMS threshold for automatic
acceptance or warning on point acceptance.
V RMS: is the vertical RMS threshold for automatic
acceptance or warning on point acceptance.
PDOP: is the PDOP threshold for automatic acceptance or
warning on point acceptance.